LX-8827 Salt Spray Testing Machine

Product Name: Salt Spray Tester Product Model:
Salt water spray testing machine is designed for surface treatment of various materials, including coating, electroplating, inorganic and organic film, anodic treatment, anti rust oil and other anti-corrosion treatment, and then test the corrosivity of its products. Meet the standard: GB10587-89 Salt Spray Corrosion Test Chamber Technical Conditions GB2423.17-85 Test Ka Salt Spray Corrosion Test Method

GB6458-86 NSS neutral salt spray test GB6459-86 ASS test - Acetic acid salt spray test

GB6460-89 CASS Test Copper Accelerated Acetic Acid Salt Spray Test IEC68-2-11 Test Ka

Performance characteristics:

 

Adopting an automatic or manual water addition system, it can automatically replenish the water level when the water level is insufficient, and the test will not be interrupted.

The precise glass nozzle (PYREX) disperses the mist evenly and naturally falls on the test piece, ensuring no crystal salt blockage.

Equipped with dual over temperature protection and low water level warning to ensure safe use.

The temperature controller uses digital display and PID control, with an error of ± 0.1 ℃.

The laboratory adopts steam direct heating method, which heats up quickly and evenly, reducing standby time.

The conical disperser of spray tower has the functions of guiding fog, adjusting fog volume and even falling fog volume.

The saturated air tank adopts the Henry's law to heat and humidify, and provides the required humidity for the laboratory.

Salt water concentration: 5%; The pH value of water is between 6.5-7.2.

 

Specification parameters: ★ The laboratory can also be made according to the size requirements of the customer to meet their needs.

Project model

KH-60 type KH-90 type KH-120 type KH-160 type KH-200 type

Laboratory size mm 600 * 450 * 400 900 * 600 * 500 1200 * 1000 * 600 1600 * 1000 * 500 2000 * 1000 * 600

Outer box size mm 1075 * 630 * 1185 1400 * 800 * 1285 1775 * 1200 * 1485 2300 * 1200 * 1485 2700 * 1200 * 1485

Laboratory temperature saltwater test 35 ℃± 1 ℃/corrosion resistance test 50 ℃± 1 ℃

Saturation bucket temperature saltwater test 47 ℃± 1 ℃/corrosion resistance test 63 ℃± 1 ℃

Acid and alkali salt water test (6.5-7.2)/corrosion resistance test (3.0-3.2)

Spray volume 1.0~2.0ml/h

The relative humidity in the laboratory is greater than 85%

Sodium chloride solution concentration 5%

Laboratory volume 108L 270L 600L 800L 1200L

Salt water tank capacity 15L, 25L, 40L, 45L, 45L

Power Supply   1∮,AC220V 10A 1∮,AC220V 15A 1∮,AC220V 20A 

Home