The leakage tracking tester is to apply a set voltage between the two electrodes on the surface of solid insulating materials and drop a specified concentration of liquid at a certain height to evaluate the leakage tracking resistance of the surface of solid insulating materials under the electric field and the polluted medium. It is suitable for lighting equipment, low-voltage electrical appliances, indoor electrical appliances, machine tool electrical appliances, insulation materials, engineering plastics, electrical connectors.
performance index
1. Studio volume: 0.5m3
2. Electrode: length ≥ 15mm; width 6mm ± 0.1; thickness 3mm ± 0.1
Material: the edge of one end of the electrode is cut into an inclined plane with an angle of 300.
3. Electrode distance: 4.0mm ± 0.1
4. The force applied by the electrode to the surface of the sample is: 1.0N ± 0.5
5. Test voltage: 100v-600v, settable
6. Test power: 2100W
7. When the short-circuit current is 1.0A, the drop value is ≤ 50V when the voltage is 600V
8. Marking judgment: 0.5A or greater current lasting for 2S
9. Drip device:
(1) Time interval of solution dropping: 30s
(2) Drop height: 30-40mm
(3) Drop size: 20mm3 ~ 23mm3
(4) Test solution
10. Force measuring device:
(0.1 ± 0.002)% ammonium chloride (nh4cz) was diluted with distilled water.